PARAM, CONTFEL
Bulk Data Entry Activates Contact-friendly elements. This is recommended when second order solids/gaskets are used with contact analysis in OptiStruct.
Parameter | Values | Description |
---|---|---|
CONTFEL | <YES,
NO, or AUTO> Defaults:
|
|
Comments
- Contact friendly elements are not required for S2S contact.