Clearance Tab

In the Clearance tab, you can define an initial clearance value and a contact direction for a contact pair.

The Contact Manager can only be used to create a clearance definition for contact pairs that have one main-secondary pair. If a contact pair has more than one main-secondary pairs, then clearance has to be defined for each main-secondary pair in the Entity Editor or in the Interfaces panel.

The Clearance tab is enabled when a main and secondary surface are selected in the Define tab, and the Small sliding and Clearance check boxes are selected in the Parameter tab.