Connectors
New Features
- Stitch Connectors
-
- A new connector type to tie Parts/Components together. There is no realization, just the equivalencing of the nodes.
- You have the option of retaining nodes and selecting the main side of the connectors as well as the remeshing method.
- xMCF File Import
-
- XMCF 3.1 compliant.
- Updated how the metadata is mapped to the connectors. The incoming information is mapped to the metadata field on the connector and is visible in the Entity Editor.
- Attachment Workflows in Connectors (HyperWorks-Specific
-
- New HyperWorks workflows are added to the Connectors Ribbon. This is a direct mapping of the Attachment workflows from the browser.
- A new Attachment type is added to the Rigid Patch attachments.
This new type projects the attachment onto a plate.

Figure 1.
- Connector Browser
-
- A new browser following the new paradigms from Model Browser.
- The different connectors are now split into separate tabs.

Figure 2.
Enhancements
- Connector Group Logic
-
- Used when dragging and dropping connectors to create a new connector group. You are prompted to create multiple groups if the connectors are scattered across many Subsystems. Each connector group is then organized into a part, and the Part is placed into the appropriate Subsystem.
- If the organization is set to Automatic, and the Connector is organized into a Subsystem different from the Subsystem the Connector Group belongs to, the ownership of the Subsystem is broken to ensure consistency.
- Single Include for Subsystem Connectors
-
- A single Subsystem is created for all the Subsystem connectors to be organized into.
- Organize connectors to current include
-
- All the connectors are organized into the active include.
- Seam connector Improvements
-
- General bugfix and quality improvements.
- Partial Connector realizations, allows you to define a percentage of acceptability for the amount the connector has successfully imprinted.
- Rule Based Realizations, adjusting the HAZ lengths to try to realize the connector automatically.
- Part/Subsystem Config Improvements
-
- Keep general connectors realized within a Subsystem when inactive.
- Prompt to realize connectors active on config change.
- Link Type reacting when changing Parts/Subsystem configurations.
Known Issues
- Miscellaneous
-
- Connector masses are no longer supported in the browser.
Resolved Issues
- Miscellaneous
-
- FE absorbing failed FEMFAT connectors.
- FE absorbing of Rigid Patches over a solid holes.
- FE absorbing not reading custom config file.
- Duplicate Rigids when realizing bolt connectors in Abaqus user profile
- FE absorbing Quad Seam issues.
- End offset information is lost on positioning connector to center.
- Added new configurations for Spring Bolts.
- Realizing an attachment twice.
- Connector groups are listed in the Model Browser.