HyperCrash

To check a spotweld

To check a spotweld

Previous topic Next topic No expanding text in this topic  

To check a spotweld

Previous topic Next topic JavaScript is required for expanding text JavaScript is required for the print function  
1.From the Menu Bar, select Connections > Spotweld > Criteria.

A Spotweld Settings window opens.

check_criteria_window_10

2.Select the appropriate criteria to check by clicking the appropriate check box.
3.Enter the desired values for each parameter (it is recommended to use the default values).
4.Validate in the pop-up dialog window with Save.
5.To reset to the default values, click Reset.
6.From the Menu Bar, select Connections > Spotweld > Check.

The folder Spotweld, Modify will open. The spotwelds which do not conform to a criteria are displayed in orange on the list.

 

To learn why the spotweld is incorrect and to modify it:

1.Select a spotweld in the list.
2.Click reviewGeneral-24 to display the spotweld and to open the modification menu.
3.Check the message in the message window to learn why the spotweld is not correct (message is in green).
4.Modify the spotweld.
5.Click Save to save the spotweld modification; or

Click Cancel to cancel the spotweld modification.

6.Click Close to close the menu.

 

See also

Spotweld

Export File