OS-E: 0880 Volume and Thermal Compliance Responses
Topology optimization of an aluminum heat sink with fins is be performed. The design space is modeled using first order Tetra elements.
Model Description
- Objective
- Minimize the thermal compliance
- Constrains
- Upper bound on total volume response
- Design Variables
- Density of each element in the design space
Results
Model Files
The model files used in this example include:
<install_directory>/hwsolvers/demos/optistruct/examples/Optim_Topol3D_Thermique_TCOMP.fem