SpiceProbeQuantity

The SPICE probe quantity properties.

Example

app = pf.GetApplication()
app:NewProject()
app:OpenFile(FEKO_HOME..[[/shared/Resources/Automation/SpiceProbeTest.fek]])   

    -- Add a cartesian graph.

cartesianGraph = app.CartesianGraphs:Add()

    -- Add a SPICE probe trace.
    
spiceProbesPlot = cartesianGraph.Traces:Add(app.Models[1].Configurations[1].SpiceProbes[1])

    -- Adjust quantity properties of the plot. 

spiceProbesPlot.Quantity.ValuesNormalised = true
spiceProbesPlot.Quantity.ValuesScaledToDB = true

Usage locations (object properties)

The following objects have properties using the SpiceProbeQuantity object:

Property List

ComplexComponent
The complex component of the value to plot, specified by the ComplexComponentEnum, e.g. Magnitude, Phase, Real, Imaginary. (Read/Write ComplexComponentEnum)
PhaseUnwrapped
Specifies whether the phase is unwrapped before plotting. This property is only valid when the ComplexComponent is Phase. (Read/Write boolean)
Type
The type of quantity to be plotted, specified by the SpiceProbeValueTypeEnum, e.g. Current or Voltage. (Read/Write SpiceProbeValueTypeEnum)
ValuesNormalised
Specifies whether the quantity values must be normalised to the range [0,1] before plotting. This property can be used together with dB scaling. This property is not valid when the ComplexComponent is Phase. (Read/Write boolean)
ValuesScaledToDB
Specifies whether the quantity values are scaled to dB before plotting. This property is only valid when the ComplexComponent is Magnitude. (Read/Write boolean)

Property Details

ComplexComponent
The complex component of the value to plot, specified by the ComplexComponentEnum, e.g. Magnitude, Phase, Real, Imaginary.
Type
ComplexComponentEnum
Access
Read/Write
PhaseUnwrapped
Specifies whether the phase is unwrapped before plotting. This property is only valid when the ComplexComponent is Phase.
Type
boolean
Access
Read/Write
Type
The type of quantity to be plotted, specified by the SpiceProbeValueTypeEnum, e.g. Current or Voltage.
Type
SpiceProbeValueTypeEnum
Access
Read/Write
ValuesNormalised
Specifies whether the quantity values must be normalised to the range [0,1] before plotting. This property can be used together with dB scaling. This property is not valid when the ComplexComponent is Phase.
Type
boolean
Access
Read/Write
ValuesScaledToDB
Specifies whether the quantity values are scaled to dB before plotting. This property is only valid when the ComplexComponent is Magnitude.
Type
boolean
Access
Read/Write