th_sae
SAE class filter.
Syntax
th_sae(xvect, yvect, class, sample_rate, debug_flag)
Arguments
- xvect
- The time vectors (seconds).
- yvect
- Response vectors to be filtered (any units).
- class
- Can be 60, 180, 600, or 1000.
- sample_rate
- Can be 2, 5, or 10.
- debug_flag
- Optional argument. Flag to turn on debug mode (points to message log). Default is off.
Example
th_sae(p1w1c1.x, p1w1c1.y, 1000, 10)
Comments
SAE class filter is a low-pass filter, which means that high frequencies are filtered.
Here, valid combination of class and sample_rate are 1000/10, 600/5, 180/5, 60/5, 180/2, and 60/2.
- LOW PASS SAE 1000/10
- LOW PASS SAE 600/5
- LOW PASS SAE 180/5
- LOW PASS SAE 60/5
- LOW PASS SAE 180/2
- LOW PASS SAE 60/2