Import PART/PID Mapping Files

Import PART/PID mapping *.csv files generated by the BOM tool into the FEMSITE utility,

Before you begin, Setup the FEMSITE Utility.

This function is used with tailored blanks, where one part consists of several property IDs. REFMODE is set to PROPERTY when referencing two properties, or it is set to PART when referencing parts.

For every PID, there is a corresponding component which is used to reference a connector. For every PART, there is a corresponding assembly which is used to reference a connector.

The mapping of components/assemblies (PID/PART) can be done using an external file. The external file specifies the assembly structure in HyperMesh.
A2126120114;QUERTRAEGER UNTER FAHRERSITZ VO LI;26120114;Shell  ;1700200;HT700T;Stahl EN 10336-  HT700T +ZE+A+O;1,50;;;;;;;;;;;;Stahl EN 10336-  HT700T +ZE+A+O;1,5;;;;;;;;;;;;
A2126160516;VERSTAERKUNG LI VO HPT.BODEN;26160516;Shell  ;1100500;HC340LA;Stahl HC340LA EN10268-1.0548+ZE+A+O / DBL:4062.51;1,00;;;;;;;;;;;;Stahl HC340LA EN10268-1.0548+ZE+A+O / DBL:4062.51;1;;;;;;;;;;;;
A2126160716;VERSTAERKUNG HI LI / HAUPTBODEN;26160716;Shell  ;1100500;HC340LA;Stahl HC340LA EN10268-1.0548+ZE+A+O / DBL:4062.51;1,00;;;;;;;;;;;;Stahl HC340LA EN10268-1.0548+ZE+A+O / DBL:4062.51;1;;;;;;;;;;;;
  1. From the menu bar, click Connectors > FEMSITE > Import PART/PID mapping.
  2. In the Select Part/Property File dialog, open the *.csv file.
    Only the parts that are correctly and completely defined are imported.
  3. If there were parts that could not be converted, the Editor dialog opens, from which you can save these parts in a separate file by clicking Save.
    Note: You can add this information again during export.