Viewing the Results

View and post-process the results in POSTFEKO.

  1. View the S-parameters on a Cartesian graph.


    Figure 1. S-parameters for the I and Q feed ports of the coil.
  2. View the currents in the 3D view and hide the phantom.


    Figure 2. Surface currents of the coil rung with the phantom hidden.

The B1+ and ratio (B1+/B1-) results are obtained from the MRI quantities automation script in POSTFEKO. The script is provided in the same folder as the CADFEKO model.

  1. Add the results from the script to the 3D view.


    Figure 3. B1+ field distribution at Z=0.


    Figure 4. Ratio of (B1+/B1-)