Temperature/Thermistor with Current Excitation

Creates channel(s) that use a thermistor to measure temperature when the thermistor requires current excitation.

Refer to the National Instruments NI-DAQmx C Reference Help file for detailed descriptions of these options, under NI-DAQmx C Functions > Channel Configuration/Creation > Create Analog Input Channels > DAQmxCreateA\ThrmstrChanlex.

AnalogInParamTempTwithCurrentEx

a: Indicates the A constant from the Steinhart-Hart-thermistor equation.

b: Indicates the B constant from the Steinhart-Hart-thermistor equation.

c: Indicates the C constant from the Steinhart-Hart-thermistor equation.

Excitation Source: Indicates the source of the excitation.

Excitation Value: Indicates the amount of excitation, in amperes, that the sensor requires.

Maximum Value: Indicates the maximum value you expect to measure.

Minimum Value:

Resistance Configuration: Indicates the configuration for resistance measurements.

Units: Indicates the units to use to return the measurement.