Submit Jobs

Use the Run VWT tool to specify the simulation time for a transient run and other setup parameters, as well as submit the actual analysis.

  1. From the Run tools, click the Run VWT tool.


    Figure 1.
  2. In the Write to ultraFluidX dialog, define run settings.
    1. In the Name of run field, specify a name for the run directory.
      Together with the current date and time, it will yield a unique run directory name.
    2. Optional: In the Run path field, specify a path for the run directory.
      The run path is set to the current working directory: the location the model was last saved or the location the file was imported from.
    3. Define the Analysis Setup and Results settings.
  3. Click Run to start the analysis.
    If you are running Virtual Wind Tunnel on a Linux system with a supported GPU, no further configuration steps are necessary. If you are running Virtual Wind Tunnel on a Windows system, you'll need to have a Linux installation of ultraFluidX available for running the solver. To run the solver from Windows:
    1. Click Export.
    2. Copy the .stl and .xml files that are created in the run directory over to Linux.
    3. Launch the solver by executing the ufxRun script, located in the installation directory at .altair/unity/bin/linux64/ufx/scripts.
      Use the "ufxRun -h" option to view the help page.

Define Settings in the Write to ultraFluidX Dialog

Before submitting a job in the Write to ultraFluidX dialog, define the Analysis setup settings.

Analysis Setup

Inflow speed
Prescribed inflow velocity at the inflow surface of the wind tunnel going into positive x-direction.
Run time
Physical run time for a transient analysis.
Time step
Time increment used for the transient analysis.
Allow time step scaling
Allow ultraFluidX to run the simulation at an elevated Mach Number to reduce the total number of time steps required to complete the run.
Maximum velocity factor
The scaling factor used to derive the maximum expected velocity within the simulation from the wind tunnel inflow speed. The maximum expected velocity is calculated as the product of the inflow speed and the maximum velocity factor. This quantity is then used to derive the time step scaling factor when time step scaling is active.
Scaling factor
The scaling factor that is used to increase the time step size when time step scaling is active. This value is computed automatically based on the maximum velocity factor, inflow speed, and peak Mach Number supported by the ultraFluidX solver.
Number of steps
Number of time steps for a transient analysis.
Fluid material
Fluid material model to use in the simulation.
Moving ground
Models the wind tunnel ground as a moving wall with a translational velocity equal to the inflow velocity.
Rotating wheels
Models parts identified as wheels as a wall, and a rotational velocity is prescribed.
Mesh preview
Write the mesh to disk before running the simulation.
Export mesh